Services -- Atlanta, GA
Reliable Service Calls and Repairs in Atlanta, GA
Your go-to solution for all electrical issues
Get an EstimateRecent Jobs and Reviews in Atlanta, GA
Our Local Reviews by City
- Alpharetta, GA (1)
- Atlanta, GA (2)
- Bowdon, GA (2)
- Carrollton, GA (2)
- Cartersville, GA (1)
- College Park, GA (2)
- Dallas, GA (1)
- Douglasville, GA (1)
- Marietta, GA (1)
- Powder Springs, GA (1)
- Rockmart, GA (1)
- Taylorsville, GA (1)
- Woodstock, GA (2)
Job Locations and Reviews
Zach Y.
We completed a comprehensive electrical upgrade, including panel relocation, surge protection, grounding, switch/receptacle replacement, circuit diagnostics, and EV charging circuit installation. The existing panel was removed and a new UL-listed load center was installed in the designated location. Branch circuits were extended and reconnected, and new breakers were installed. A whole-home surge protection system was added for enhanced equipment protection. The grounding electrode system was upgraded, and all switches and receptacles were replaced. Circuit diagnostics identified and repaired power loss issues. A dedicated 120-volt EV charging circuit was installed outdoors. All work was inspected and tested for proper operation.
Atlanta, GA 30306
Zach Y.
We completed a comprehensive electrical upgrade, including relocating the main panel from the stairwell to a designated closet. We installed a new UL-listed load center, extended wiring, and added new breakers. A whole-home surge protection system was installed for enhanced protection. The grounding electrode system was upgraded, and all switches and receptacles were replaced with GFCI protection where needed. Circuit diagnostics restored power to the kitchen vent hood and rear room light. A dedicated 120-volt EV charging circuit was installed outdoors. All new equipment and repairs were inspected and tested for proper operation.
Atlanta, GA 30306
Nathan E.
I successfully installed two customer-supplied basic light fixtures, connecting them to the existing 120V switched lighting circuits. The fixtures were mounted at heights up to 10 feet. Proper code-compliant junction boxes were installed and/or replaced to securely support and conceal all electrical connections. Each connection was meticulously secured and tested to ensure correct operation. The installation process adhered to all safety standards, providing reliable and compliant lighting solutions.
Atlanta, GA 30313
Nathan E.
We conducted a thorough diagnostic on the under-cabinet kitchen lighting and the exterior front door light. Testing revealed a complete loss of power in both systems. The under-cabinet lighting will be restored by replacing the existing transformer with a new 12V 60W unit. For the exterior light, we will locate and repair the power loss in the circuit. Additionally, we removed the existing dining area light fixture and installed a new chandelier provided by the customer, ensuring all electrical connections are secure and the new fixture operates correctly.
Atlanta, GA 30339
Colton P.
I was called to address an issue with the garage lights not functioning. After examining the wiring, it was clear that the previous installation was incorrect. The switch lacked a neutral connection, and the circuit was linked to the wrong breaker. The previous installer had suggested AFCI breakers, but the correct requirement was a 15-amp Square D single-pole GFCI breaker. I installed this breaker, rehung the light fixture, and corrected the wiring in three electrical boxes. After thorough testing, I confirmed that the garage lights are now operating correctly.
Atlanta, GA 30345
Review
Professional and competent
Colton P.
Upon inspection, we identified a double-tapped circuit breaker that posed a safety risk. We promptly replaced the faulty breaker to ensure proper functionality and safety. Additionally, we installed Ground Fault Circuit Interrupter (GFCI) protection on the specified receptacles. This installation safeguards against electrical shocks by automatically cutting off power when a ground fault is detected. Our team ensured all work met local electrical codes and standards, providing peace of mind for the new homeowner.
Atlanta, GA 30324
Colton P.
I successfully installed a NEMA 14-50 EV outlet on the side of a townhouse, ensuring it was securely mounted and weatherproofed. The installation included running the necessary wiring and connecting it to the main electrical panel. I also installed a protective cover to safeguard the outlet from the elements. The job was completed efficiently, and the outlet is now ready for use.
Atlanta, GA 30363
Colton P.
Today, I assessed the customer's concern with their built-in gas range and oven. The appliance, securely fastened to the countertop, prevented safe removal for inspection. Consequently, I couldn't access the electrical connections or the receptacle behind the stove. I recommend hiring a qualified technician to safely disconnect the appliance from the countertop. Once accessible, I can inspect the electrical connections, including those for the convection fan, and test the receptacle. Due to the appliance's current position, no further electrical diagnosis was possible.
Atlanta, GA 30307
Nathan E.
The existing landscape lighting fixture had a broken top section and was not receiving power due to severed wiring in the basement. I installed a new pole light head to replace the damaged portion. Although the fixture is now complete, power restoration is not part of this service and will need to be addressed separately.
Atlanta, GA 30310
Zach Y.
I installed six recessed lights, including new wiring and a dimmable switch. A ceiling fan was installed with a new switch, using the owner's supplied fan. A chandelier was replaced with an owner-supplied ceiling fan in the master bedroom, and similar replacements were done in two other bedrooms. A whole home surge protection system was installed. A breakfast room chandelier was replaced with a new fixture provided by the owner. All switches and receptacle outlets in the living room and master bedroom were replaced.
Atlanta, GA 30328
Nathan E.
I successfully installed two new exterior outlets to power outdoor string lights. The process began by extending power from an existing suitable circuit. I then installed exterior-rated electrical boxes and weather-resistant receptacles to ensure durability and safety. Proper weatherproof in-use covers were added for added outdoor protection. All wiring and connections were meticulously secured and tested to ensure proper operation. The installation was completed with attention to detail, providing a reliable and safe solution for the customer's needs.
Atlanta, GA 30318
Nathan E.
We replaced a faulty bathroom exhaust fan, installing a new one that required replacing two existing junction boxes for safe electrical connections. A circuit extension was necessary to power the new fan. Additionally, we installed two customer-supplied light fixtures. To safeguard the home’s electrical system and electronics, we recommended and installed a Type 1 whole-home surge protector. Note that any drywall or finish repairs for concealed wiring are not included in the scope of work.
Atlanta, GA 30341
Nathan E.
We carefully removed the old light fixture, ensuring no damage to the surrounding area. The original junction box was safely capped off to prevent any electrical hazards. A new junction box was installed at the desired location, and the wiring was meticulously rerouted to accommodate the new setup. The customer-supplied light fixture was then installed, with all connections securely fastened. Each connection was thoroughly tested to ensure proper operation, and the fixture was verified to be functioning correctly. The job was completed to the highest standards of safety and quality.
Atlanta, GA 30306
Nathan E.
Upon arrival, we met with the customer to discuss their needs. They requested a new light fixture above the dining room table. We began by determining the precise location to center the fixture over the table. A new junction box was installed to support the fixture. This involved careful measurement and precise wiring to ensure it was level and secure. The new light fixture was then installed, connected to the existing lighting circuit, and tested for functionality. The installation was completed to ensure it was clean, centered, and met all electrical codes.
Atlanta, GA 30306
Nathan E.
I installed a new fan motor equipped with thermostat control, ensuring seamless integration with the existing fan housing. This involved precise wiring connections to maintain optimal functionality. The process included assessing the current setup, carefully disassembling the old motor, and installing the new components. I tested the system to confirm proper operation and adjusted settings to ensure efficient performance. The job was completed with attention to detail and adherence to safety standards.
Atlanta, GA 30312
Zach Y.
I meticulously removed the damaged service entrance SEU weatherhead, ensuring all existing service entrance conductors were safely disconnected. I replaced the weatherhead with a new utility-rated service attachment eye bolt mast anchor, aligning it precisely to meet current NEC standards. The new assembly was securely attached, and I re-terminated the conductors, preserving any suitable existing wiring. I confirmed all electrical connections were secure, verified proper conductor support and clearances, and ensured the service entrance assembly was weather-resistant. The work concluded with thorough testing, cleanup, and disposal of replaced materials.
Atlanta, GA 30310
Colton P.
I removed unused low-voltage wiring throughout the home, including coaxial cables, security system control box wiring, and speaker system wiring. All wiring was neatly tucked into wall cavities. Two telephone jacks were also removed, with wiring safely pushed into the walls. The customer will handle any necessary drywall repairs.
Atlanta, GA 30308
Colton P.
Following a recent lightning strike, I conducted a thorough inspection of the electrical system. The damage required multiple critical components to be replaced or updated to ensure safety, reliability, and code compliance. The work included replacing all three electrical panels, installing three whole-home surge protectors, and an additional surge protector at the 400-amp meter. The service entrance conductors were replaced, and two new air conditioning disconnects were installed. I also added an exterior GFCI receptacle and a floor receptacle. Seven interior decorator-style receptacles were replaced, and a Level 3 smoke alarm package was installed. Required branch circuit breakers were updated with AFCI breakers. All work was completed with the necessary permits and in accordance with current codes.
Atlanta, GA 30327
Nathan E.
I installed two new exterior wall sconces on each side of the entry door. Since no junction boxes were present, I extended the existing front entry light circuit, installed two code-compliant junction boxes, and completed all necessary wiring. I connected the sconces to the existing switch, ensuring all three fixtures operate together. This involved precise wiring, secure fixture attachment, and thorough testing to verify proper operation, all in compliance with current NEC standards.
Atlanta, GA 30319
Colton P.
I completed a project involving the installation and repair of several electrical outlets and outdoor lighting fixtures. The work included diagnosing and fixing issues with three electrical outlets, two of which were inside the premises and one outside. Additionally, I addressed problems with some outdoor lighting, ensuring they functioned properly. The outlets were tested for proper voltage and functionality, while the outdoor lights were checked for brightness and operational status. All work was performed efficiently to ensure safety and compliance with electrical standards.
Atlanta, GA 30318
Colton P.
I successfully replaced the existing exit signs in the retail store with new ones. The process involved removing the old signs, ensuring the wiring was properly disconnected, and installing the new signs in their place. I double-checked the functionality of each new sign to confirm they were working correctly. The job was completed efficiently, ensuring the store met safety regulations.
Atlanta, GA 30342
Nathan E.
I conducted a thorough inspection of the electrical panel due to customer concerns about the circuit breakers. The inspection revealed a burnt bus bar beneath the main breaker, rendering the panel unsafe. Replacing individual breakers wouldn't resolve the issue. I recommended replacing the entire panel with a new, code-compliant load center and properly sized circuit breakers. All new breaker terminations were completed according to current NEC standards to ensure a safe and reliable electrical system.
Atlanta, GA 30318
Nathan E.
a comprehensive redevice to replace all receptacles and ensure proper wiring throughout the entire home, or a targeted redevice focusing on specific rooms based on the customer's preference. Our team meticulously assessed each affected area, ensuring safety and compliance with electrical standards. We provided detailed explanations of both options, allowing the customer to make an informed decision. Ultimately, we executed the chosen plan efficiently, restoring full functionality and safety to the home's electrical system.
Atlanta, GA 30318
Review
I had an outstanding experience with Surepoint Electric. The technicians, Zach and Mitchell, were exceptional from start to finish. They arrived on time, were professional, courteous, and took the time to explain the work they were performing. Their attention to detail, technical expertise, and commitment to quality were evident throughout the entire job. They worked efficiently, kept the work area clean, and made sure everything was completed safely and to the highest standard. It’s refreshing to work with technicians who truly take pride in their craft. I highly recommend Surepoint Electric, especially Zach and Mitchell, to anyone looking for reliable, knowledgeable, and professional electrical service. Thank you both for a job exceptionally well done!
Nathan E.
We replaced the existing interior electrical load center with a new UL-listed unit, enhancing safety and reliability. The old panel was removed, and new UL-listed circuit breakers were installed. Branch circuits were transferred, terminated, and identified in the new panel. AFCI protection was added to applicable 120-volt circuits to reduce arcing fault risks. A Type 1 whole-home surge protection system was installed at the panel to safeguard appliances and electronics. All labor, materials, and system testing were included, with any additional code issues documented separately.
Atlanta, GA 30303
Colton P.
Wendy contacted us about recent rewiring work we completed. She requested a follow-up appointment for a technician to review the job. During the initial visit, we assessed the electrical system, identified necessary upgrades, and executed the rewiring to ensure safety and efficiency. We are now ready to discuss pricing details and any additional services she might need. Please call 954 417-7000 to schedule your appointment.
Atlanta, GA 30345
Frequently Asked Questions
Questions About Service Calls and Repairs
We’ve got answers to your common questions